Ftu

  1. Fingertip Units for Topical Steroids
  2. Trường Đại học Ngoại Thương
  3. Fingertip unit
  4. Turbidity
  5. FTU


Download: Ftu
Size: 3.30 MB

Fingertip Units for Topical Steroids

One FTU is the amount of topical steroid that is squeezed out from a standard tube along an adult's fingertip. (This assumes the tube has a standard 5 mm nozzle.) A fingertip is from the very end of the finger to the first crease in the finger. One FTU is enough to treat an area of skin twice the size of the flat of an adult's hand with the fingers together (ie a 'handprint'). Two FTUs are about the same as 1 g of topical steroid. Therefore, for example, say you treat an area of skin the size of eight adult hands. You will need four FTUs for each dose. (This is 2 g per dose. If the dose is once a day, then a 30 g tube should last for about 15 days of treatment.) The following are further examples: Area of skin to be treated (adults) Size is roughly FTUs each dose (adults) A hand and fingers (front and back) About 2 adult hands 1 FTU Front of chest and abdomen About 14 adult hands 7 FTUs Back and buttocks About 14 adult hands 7 FTUs Face and neck About 5 adult hands 2.5 FTUs An entire arm and hand About 8 adult hands 4 FTUs An entire leg and foot About 16 adult hands 8 FTUs Fingertip units and children An FTU of cream or ointment is measured on an adult index finger before being rubbed on to a child. Again, one FTU is used to treat an area of skin on a child, equivalent to twice the size of the flat of an adult's hand with the fingers together. You can gauge the amount of topical steroid to use by using your (adult) hand to measure the amount of skin affected on the child. ...

Trường Đại học Ngoại Thương

Trường Đại học Ngoại thương là một trong những trường đại học đi tiên phong trong đổi mới giáo dục bậc Đại học. Nhà trường luôn chú trọng tạo lập một môi trường rèn luyện và học tập cho sinh viên nuôi dưỡng và phát triển tiềm năng, quan tâm phát triển các năng lực khác bên cạnh năng lực chuyên môn của sinh viên.

Fingertip unit

Fingertip units is a term coined by CC Long and AY Finlay who, in an article published in 1991, described a convenient way to measure how much cream to prescribe to a patient with skin disease. Accurate prescription is particularly important for topical steroids. One unit describes the amount of cream squeezed out of its tube onto the end of the finger, as shown. Fingertip unit The quantity of cream in a fingertip unit varies with age: • Adult male: 1 fingertip unit provides 0.5 g • Adult female: 1 fingertip unit provides 0.4 g • Child aged 4 years – approximately 1/3 of adult amount • Infant 6 months to 1 year – approximately 1/4 of adult amount. The amount of cream that should be used varies with the body part: • One hand: apply 1 fingertip unit • One arm: apply 3 fingertip units • One foot: apply 2 fingertip units • One leg: apply 6 fingertip units • Face and neck: apply 2.5 fingertip units • Trunk, front and back: 14 fingertip units • Entire body: about 40 units. Example An adult female applies a cream once daily to both arms. She uses 2.4 g in one day (2 arms x 3 fingertip units x 0.4 g = 2.4 g). This is 16.8 g per week (7 x 2.4 g). A 30 g tube should last her two weeks. But if she applies it twice daily (4.8 g/day), the tube will be finished in less than a week (33.6 g/week). An adult male applies a cream once daily to the dorsal and volar surfaces of both feet and both hands. He uses about 3 g per day (2 feet x 2 units PLUS 2 hands x 1 unit, x 0.5 g = 3.0 g). This w...

Turbidity

• العربية • Català • Čeština • Deutsch • Eesti • Español • فارسی • Français • 한국어 • Hausa • Hrvatski • Bahasa Indonesia • Italiano • עברית • Қазақша • Кыргызча • Bahasa Melayu • Nederlands • 日本語 • Polski • Português • Română • Русский • Simple English • Suomi • Svenska • தமிழ் • ไทย • Українська • 中文 • v • t • e Turbidity is the cloudiness or Turbidity (or haze) is also applied to transparent solids such as glass or plastic. In plastic production, haze is defined as the percentage of light that is deflected more than 2.5° from the incoming light direction. Causes and effects [ ] Turbidity in open water may be caused by growth of In drinking water, the higher the turbidity level, the higher the risk that people may develop [ citation needed] In water bodies such as For many [ citation needed] Measurement [ ] The measurement of turbidity is a key test of both [ citation needed] There are two standard units for reporting turbidity: Formazin Nephelometric Units (FNU) from ISO 7027 and Nephelometric Turbidity Units (NTU) from USEPA Method 180.1. There are several practical ways of checking water quality, the most direct being some measure of JTU) is essentially the inverse measure of the length of a column of water needed to completely obscure a candle flame viewed through it. The more water needed (the longer the water column), the clearer the water. Of course water alone produces some attenuation, and any substances dissolved in the water that produce color can attenuate some...

FTU

Category filter: Acronym Definition FTU Foreign Trade University (Hanoi, Vietnam) FTU Flight Training Unit FTU Formal Training Unit FTU Flying Training Unit (USAF) FTU Federation of Trade Unions (Hong Kong) FTU Marillac (Madagascar airport code) FTU Fishing Tackle Unlimited (Texas) FTU Florida Technological University (now University of Central Florida) FTU Florida Times-Union (newspaper) FTU Forskning og Teknologisk Udvikling (Danish: research and technological development, aka: RTD) FTU Fitness Training Unit FTU Fiber Termination Unit (fiber optics) FTU Flight Test Unit FTU Fonds de Travaux Urbains (French: Urban Works Fund) FTU File Transfer Utility FTU Full Time Unit FTU Fleet Training Unit (US Navy) FTU Tensile Ultimate Stress (metals) FTU Female-to-Unknown (gender) FTU Fijnmechanische Techniek Utrecht (Dutch mechanical engineering company) FTU First Time User FTU Formazin Turbidity Unit FTU Finger Tip Unit (medication application) FTU Fault-Tolerant Unit FTU Field Technical Unit FTU Fixed Treatment Unit FTU Frederick Taylor University (est. 1994) FTU Field Torpedo Unit (US Navy) FTU French Tactical Unit (gaming clan) FTU Free Time Unlimited (Amazon) FTU First Training Unit FTU Freight Terminal Unit FTU Ferry Transport Unit FTU Fan Terminal Unit In conclusion, in the current study quails fed Ca-P-deficient diet supplemented with 5 [micro]g [kg.sup.-1] of 1[alpha]-OH[D.sub.3] in combination of 500 FTU [kg.sup.-1] of phytase were able to achieve the same tibia ash and C...

Tags: Ftu Windows 11